(C) 2011 American Institute of Physics. [doi:10.1063/1.3575178]“
“A 43-year-old patient with CH5424802 ic50 end-stage renal disease, a hypercoagulable condition and 100% panel reactive antibody was transferred to our institution with loss of hemodialysis access and thrombosis of the superior and inferior vena
cava, bilateral iliac and femoral veins. A transhepatic catheter was placed but became infected. Access through a stented subclavian into a dilated azygos vein was established. Desensitization with two cycles of bortezomib was undertaken after anti-CD20 and IVIg were given. A flow-positive, cytotoxic-negative cross-match live-donor kidney at the end of an eight-way multi-institution domino chain became
available, with a favorable genotype for this patient with impending total loss of a dialysis option. The patient received three pretransplant plasmapheresis treatments. Intraoperatively, the superior mesenteric vein was the only identifiable patent target for venous drainage. Eculizumab was administered postoperatively in the setting of antibody-mediated rejection and an inability to perform additional plasmapheresis. Creatinine remains normal at 6 months posttransplant and flow cross-match is negative. In this report, we describe the combined use of new agents (bortezomib and eculizumab) and find more modalities (nontraditional vascular access, splanchnic drainage of graft and domino paired donation) in a patient who would have
died without transplantation.”
“In this work, nonisothermal film blowing process analysis for non-Newtonian polymer melts has been performed theoretically by using minimum energy approach and the obtained predictions were compared with both, theoretical and experimental data (internal bubble pressure, take-up force, bubble shape, velocity and temperature profiles) taken from the open literature. selleck kinase inhibitor For this purpose, recently proposed generalized Newtonian model depending on three principal invariants of the deformation rate tensor, D, and its absolute defined as root D.D p has been used. It has been found that film blowing model predictions are in very good agreement with the corresponding experimental data. (C) 2011 Wiley Periodicals, Inc. J Appl Polym Sci 122: 2807-2820, 2011″
“Polymer-shelled micro-bubbles are employed as ultrasound contrast agents (UCAs) and vesicles for targeted drug delivery. UCA-based delivery of the therapeutic payload relies on ultrasound-induced shell rupture. The fragility of two polymer-shelled UCAs manufactured by Point Biomedical or Philips Research was investigated by characterizing their response to static overpressure. The nominal diameters of Point and Philips UCAs were 3 mu m and 2 mu m, respectively. The UCAs were subjected to static overpressure in a glycerol-filled test chamber with a microscope-reticule lid.